Luffing Winch Stop Monitoring Fault code.

While operating the MR 329 The operator lost boom down function. Fault Code 2074.25501 was listed in messages.  The Potain Fault code app had no definition of the fault code. I instructed the operator to turn off the crane and restart it. When the crane was running again the code was cleared and the crane regained boom function.

Attached is the Code and the code description from Potain.

25501 Stop monitoring definition