INCLINOMETER FAILURE
GMA CCT MENU CCS MENU
HUP will not enable Top Site
Went through the procedures several times, but would not turn on Top Site. Serial number was not in CCS computer. Program serial number and Top Site now works.
Slew Drive Manual for HUP’s (ACS 380)
HUP Sensor List
Weathervane on releasing on Hup (Slew Brake not engaging)
Need to raise handle on brake and slide cam plate (lock plate) into position. Lift up on brake handle, and the plate should return to the “unlocked” position automatically.
Video showing proper operation
If not, remove weathervane coil plate with the 2 bolts, but be careful as the return spring is underneath it. Remove the 4 screws holding the lock plate in place and clean bottom of lock plate and surface below it on the brake coil. When reinstalling, make sure that the nut on the weathervane coil is not too tight, as it can interfere with free movement.

Hoist Motor Not Working in Very Cold Temperatures
TA20-236-A – Operating mode for TUN function ATV320 on HUP cranes_EN (2)
Suggestion per France
Here is a procedure for making a motor tune on the ATV320 hoisting motor drive.
In green : menu and parameters of the drive HMI.
For this operation, the crane must be in « work » configuration.
Unlock the hoisting drive :
Mod (Non) / Cod- / Cod / enter : 2024
(press esc, esc, esc to go back to the main menu)
Change command channel from CANopen to terminal (needed for manual tune ) :
Conf / Full / Ctl- / Fr1 / change Can for AI1 (looks like A11) Must Scroll to the left
Make the motor tune :
Conf / full / Drc- / ASY- / Tune change No for YES then press enter for 5 seconds to launch the tune.
Check that the tune is done
Conf / full / Drc- / ASY- / TUS this parameter displays Done if the tune is well done.
If possible note the new value of RSA parameter (unable to do)
Conf / full / Drc- / ASY- / rSA read and note the value.
Re-change the command channel from terminal to CANopen
Conf / Full / Ctl- / Fr1 / change AI1 for Can
Crane won’t Slew, 5091 error message on Slew Drive
Manual shows error at current supply to Slew Drive. Crane was running on a new generator (14 hours) and failed. United Rentals came out and put a load bank on the generator and its working again.