Remote keeps kicking out and getting errors. Swapped whole remote and works fine. Going to get antenna extension from HBC to see if it will help signal strength.
Autec Remote Display Weight
To zero out weight on display, open receiver box in control panel. Switch rotary dial to 1. This should change display screen to set Dta. Dta is the minimum limit. Set to 0 with no load on the hook. Small buttons on receiver near rotary switch are + and -. Once it’s zero and, hold both buttons until the remote display says “result: success”. Dtb is the maximum limit and both need calibrated to be accurate on display. Dtb needs to be 50% of maximum load.
Liebherr Login Code
When logging into the diagnostic menu, code is (month + date) + (hour + minutes) example if it is 4/15 at 14:30…its (19) + (44) = 63 code will be 63 for one minute. Hit the “+” 63 times to get to correct code
Liebherr 30157 wind speed not displayed on remote
Wind speed not displayed on remote or control panel display. It is not enabled on the control panel. Follow instructions in manual 4-135. Login, next page, set, function key with anenometer displayed
Potain MA13 Drive Error Short Circuit and no read out on Hoist Drive
Went to set up crane
Smoke coming out of hoist drive and trolley drive getting short circuit code
Unhooked output side of hoist and still tripping breaker. Bad Drive
Unhooked output side of trolley drive still getting error bad drive
Replacement drives Part Numbers
Trolley (New updated drive only) 8201-1312 Kit to upgrade from Altavar 58 8200-7514
Swing W-81406-89 Kit 8200-0671
Hoist A-81406-46 Kit 8200-7510
Liebherr 30157 jerky when swinging to the left or slewing left
Crane was oscillating when swinging to the left.
Only was happening when it was cold.
Changed out encoder.
Need snap ring pliers and lots of zip ties to do it. Took about 1.5 hours
Transformer wiring
Internally, H1 to Black on output cord and H10 to White on output cord. Green to ground and red goes to nothing.
Externally on output cord end, red is X, black is Y, white is W and green to ground
Potain 27148 – shutdown immediately after start up
Igo T 85 where drives immediately shut down at start up. Left drive (hoist) shows TNF and right drive (trolley) shows USF, swap leads at generator (ie swap red/white or black/red). It is out of phase
Remote Pass code for Potain 27148
To get into remote it is 0071
Turn remote off and then hold start button next to screen when you turn on
Should come up so you can change groups
HUP passcode
HUP 40/30 pass code for remote 8528