Potain Igo T85A (27148) – Greaser not working

Amber light on the control panel with grease symbol on, but grease reservoir full.

Light comes on when it’s working, and when grease level is low.  Grease pump motor is 24 volts DC.  Found 8 volts.  Removed 3 pump bolts and water poured out.  Circuit board was shorted.  Replace assembly.

(Note.  K600M must be engaged to activate greaser circuit.)