T85 keeps shutting off

Fault is 1-230-026, slew encoder failure.  Instead of changing to “disconnected” in the slew drive, changed to “Partially Open Loop”.  Allowed crane to continue operation.

Menu to change parameters in Slew Drive

Menu

Parameters

Complete list

96 System Menu

02 Pass code

Last two are 71

Back

Menu 74

Menu 12

Partially Open Loop

 