Fault is 1-230-026, slew encoder failure. Instead of changing to “disconnected” in the slew drive, changed to “Partially Open Loop”. Allowed crane to continue operation.
Menu to change parameters in Slew Drive
Menu
Parameters
Complete list
96 System Menu
02 Pass code
Last two are 71
Back
Menu 74
Menu 12
Partially Open Loop