Hoist drive shuts off immediately after it starts E65 code

When trying hoist or lower line, drive immediately shuts off.  Display on drive E65.  The drive is not receiving a signal from speed sensors (there are 2 on the motor).  Found 2 broken wires at crimped terminals on Speed Card (X3B).