Turning on/off Aneometer on Liebherr 81k.1

Turn Dianostic key in Side panel

Enter Code on Screen

Month+Day+Hour+Minute

You have one minute to enter code before it changes to the next minute

Hit F6 for Set Screen

Push and HOLD for 3 Second F3

This should remove or add X through the Wind Speed Senor

You can then hit F2 to go to next page to change units

You can then hit F2 again to change warning and Load Plus