Crane shuts down during operation

Crane is shutting down during operation, however no fault is displayed and the operation symbol on the LMI bottom right goes from a red circle to flashing green almost immediately.  After searching for the fault history (no active faults), found a list of Can Bus faults.

2032.33057 CAN bus CMD: CAN error bus off

2032.33058 CAN bus CMD: CAN alarm bus error

2032.33040 CAN bus CMD: CAN saturation

2032.33058 CAN bus CMD: CAN alarm bus error

2032.33057 CAN bus CMD: CAN error bus off

2032.33040 CAN bus CMD: CAN saturation

Located on the Can Bus CMD (Command) ‘channel’ is the crane’s modem.  Disconnect the top 3 and the bottom large connector.  Crane will restart and work