With the addition of the hoist drive on the HDT 80, during rapid lowering, drive may fault and need reset. Drive displays Ou (Ov- overvoltage) Changed parameter C1-02 (deceleration time 1) from.8 seconds to 1.2 seconds.
This is an overvoltage of the dc bus because with a decending load the hoist motor may act as a generator and overcharge the dc bus. The braking resistor may be undersized and the dc bus cannot discharge fast enough. This parameter change allows for a slower deceleration to discharge.

Sweet! Is there any password or anything special to get in to that menu?
There is no password for this parameter