Crane load indication accuracy

1917.46(a)(1)(ii)

The accuracy of the load indicating device, weight-moment device, or overload protection device shall be such that any indicated load (or limit), including the sum of actual weight hoisted and additional equipment or “add ons” such as slings, sensors, blocks, etc., is within the range between 95 percent (5 percent underload) and 110 percent (10 percent overload) of the actual true total load. Such accuracy shall be required over the range of daily operating variables reasonably anticipated under the conditions of use.

AC not working in cab

Here is the condensed version of the expanded troubleshooting tree.

Issue

AC/Heat unit not working

Cause

The AC unit not working can be caused by multiple problems, follow the procedures in the resolution notes to find out what is wrong with the unit, or if it need replaced

Resolution

  1. Check the circuit breakers that control the AC and heat units
    2. Check phase detector inside AC unit to be sure it has 2 lights
    3. Replace AC controller to the left of seat
    4. Check to see if the Condenser fan on the back of the cab runs when AC is selected, if not, check the fuses
    5. Try using the “Defrost” setting and see if the AC turns on
    6. Access AC unit and check to see if all the sensors are connected and working properly
    7. If you cannot figure out why the AC unit is not running, order a new unit and replace it

TA23-450-C – Troubleshooting flow chart for the ultraview cab air conditioning system_EN

MDT – Tech Tip Videos

MDT Tech tip Playlist

Below is a library of videos. If you have a customer with one of these issues, send them the link to our Youtube channel to help free up your time.

LMI Fault Troubleshoot – Crane won’t start, how to access the fault stack Youtube Link

LMI service code – How to enter a service code using the LMI Youtube Link

Loss of cab power – Instructions to check for tripped circuit breaker Youtube Link

Turning off slew encoder – How to enter the VFD to turn off the slew encoder Youtube Link

Checking Correct Power and Phase – Where to look for the correct phase Youtube Link

Switching from 4 part to 2 Part – How to switch the hook block Youtube Link

Custom operator controls – How to change or adjust the operator controls Youtube Link

Emergency hoist release – How to lower a load without crane power Youtube Link

CCS Serial number lookup – How to lookup the serial # in the processor Youtube Link

Inputting a new serial number into CCS – How to input a new serial # into the processor Youtube Link

Manual weather vane – How to put Topless cranes into weather vane manually Youtube Link 

Wireless Remote Diagnostics – How to check the functionality of the wireless remote Youtube Link 

Weathervane detection microswitch replacement – How to locate and remove the weathervane detection microswitch. Youtube Link