Tried using Crane CCS code to get into maintence mode and it remains locked.
Must use technican CCS code to get to that menu
See attached for Access rights for either Crane code for Technican Code
Tried using Crane CCS code to get into maintence mode and it remains locked.
Must use technican CCS code to get to that menu
See attached for Access rights for either Crane code for Technican Code
Time shows 12:00AM and date shows 1/1/00. Fault (00024.00083) show SCM date and time incorrect.
Enter Mounting Menu (6). Enter System Date Menu (5) Reset date and time.
This is for older HUP’s that use 4 digit password.
After service and teach-in of a Hup 32-27 The jib was required to be folded for weathervane. Went through the book to confirm the steps were completed in order and done correctly.
The crane would fold the jib tip but not the complete jib. A red x would appear when weathervane target was selected.
The image for the Trolley position if glanced at quickly is difficult to decern the correct trolley placement.
Note: The trolley must not be in the transport position.
Trolley in, until the trolley is completely inside the first jib section. This will allow the jib to fold for weathervane.

According to ABB drive manual
Code: 3381
Fault: Output phase loss
Programmable fault: 31.19
Probable Cause: Motor phase loss
Motor circuit fault due to
missing motor connection (all
three phases are not
connected).
What to do: Connect motor cable.
K600M contactor was not energizing
Crane will not swing at start up, but will kick out of weathervane. Manually lift swing brake and attempt swing again, and crane will swing normally, however will not brake normally.
Look for +20VDC at V100F, and verified. Look for +20VDC at K600M #7 and verified. Found no voltage at K600M #8. Although contactor was energized, contacts were not closed. Replace K600M.
**Note** this was specifically on a Hup 32-27 which only has 1 swing motor. Condition may be different with 2 swing motors on Hup 40-30
While Programming the CCS for Top Zone on Submenu (66) the crane will not accept the 10 digit Activation code. And will not change from (Zone not activated) to (Zone activated). The crane doesn’t know its serial number. You need to go to Submenu (60 Mounting then to Serial) then put in the serial number. Once you put the serial number in you need to go back to the Top Zone programming in the CCS and follow the steps in reprogramming the Top Zone.
To activate Top Zone go to page 5-171 in your operators manual and follow the steps, to be able to set your Zones. After activating Top Zone in the CCS, you need to go in to teachin-program on your remote and set your degree point. Then you should be able to create your Zones.
Voltage is reading 488 volts. It’s too much voltage. Need to reprogram hoist drive per service bulletin.TJF Service Bulletin
Below is a library of videos. If you have a customer with one of these issues , send them the link to our Youtube channel to help free up your time.
Hup remote Functions – Remote button, switch and screen displays. Youtube Link
VFD Location and Error code – Location of VFD’s, Breaker locations, and Where to look for error codes. Youtube Link
Hup Handheld remote – How to plug in and start crane with wired handheld remote Youtube Link
Checking power – How to check voltage at the filter. Youtube link
Manual weather vane – How to manually engage weather vane and confirm it is in weather vane via the remote Youtube Link
Automatic weather vane – how to activate the weather vane with push button Youtube Link
Hoist block and trolley at end of shift – Where to place the trolley and hoist block to help when ice/snow accumulation develops Youtube Link
Fast Charge Battery – How to remove and install batteries Youtube Link
Taking out of weather vane – How to get into work mode and confirm you’re out of weathervane. Youtube Link
Daily inspections – Base Level, Power cable inspection, Wire rope inspection, Trolley inspection Youtube Link
Start instructions – How to start with a generator, connect remote and confirm connection Youtube Link
Weathervane to working mode confirmation – Hup with dual slew motors. Youtube Link
Wireless Remote Diagnostics – How to check the functionality of the wireless remote Youtube Link