Could not calibrate Moment sensors

During erection, could not validate 0 moment in Teach In.  Both moment sensors were reading 0 mA.  If moments sensors are too close or too far away, they will be “out of range” and read 0 mA.  Need to be adjusted by gap once the crane is in the air and all of the weights are in.

5.5 mm is what it needs to be set at.

Thanks J MF P

MDT 109 (30180)

Customer complained that the AC power in the cab was not working.  When asked, the customer still had lighting, but the AC plug ins were not working.  Found that the circuit breaker Q104F was tripped.

**note**  when circuit breaker was tripped the indicator was green.  When it is working, the indicator is red