Potain Igo T85A (27148) – Greaser not working

Amber light on the control panel with grease symbol on, but grease reservoir full.

Light comes on when it’s working, and when grease level is low.  Grease pump motor is 24 volts DC.  Found 8 volts.  Removed 3 pump bolts and water poured out.  Circuit board was shorted.  Replace assembly.

(Note.  K600M must be engaged to activate greaser circuit.)

Potain 22131 HUP Swing

Customer said crane would only swing to a certain point and Stop. Went out and check slew limiter and it looked good. Went into teach on remote and went to swing and re validated it and it worked fine after that

Boosting Antenna Signal on Autec Receiver

According to Ken (716-220-5153) only do this when adding the “long” antenna or you could damage the receiver (yellow box).

“S1” is trolley out first speed
“S2” is trolley in first speed
DIP switch #1 & #2

-Main power off, remove 4 screws on transmitter. Find DIP switch #2 and move it to its opposite position.
-Main power on, and remote on press start button. Crane should start up, but not honk
-Hold the start button, function button (black button on opposite side of start button) and S1 (trolley out first speed)
-This enters you into the service menu and toggle through the menu using S2 (trolley in first speed) until you reach RF Power (should read normal)
-S1 until the the RF Power says “MAX” (it goes normal, high and max)
-Press start button, function button and S2 and it read Result OK when complete.
-Shut off main power, switch DIP switch #2 to original position and replace cover

Autec receiver DIP switches