All drives shut off, when raising jib after telescoping

After telescoping to the correct height, went to raise jib to 0 degrees, and all the drives would shut off.  It would go down, but wouldn’t come up.  Tomas said on “SOME” T85’s and “SOME” generators (pre-emission), the jib reatining winch can trip the phase detector.  Jumper the 2 red wires together in 1 slot (11 & 14), and bypass phase detector.  Once operation is complete move wires back.