List of HUP sensors that you will find on the remote
The operator starts crane and all functions work except hoist. When he tries to hoist drive throws TJF Fault.
The voltage on the generator is at 500 V had him turn it down to 480V restart the crane and it all works fine
One number the memo does not cover is the 2 at the end of your mast name.
K447E2
The 2 just means that it is the most recent revision (non structural) to make it compliant with different safety standards. In our case it would be OSHA.
9999
Dusty,
Full hoist rope length including rope to rig the jib and maintain 3 wraps is approximately 310-320m. At 30m of HUH, the crane would need approx 220m of rope in total to work in 4 part. You might, therefore, remove about 100m of rope if you discover that the rope is not reeving properly at the lesser operating mast and HUH height.
![]()
Login into Manitowoc Direct, E-Tech, Dealer Softs- Tools, Soft-Programme and Download the appropriate ccs version for your crane.

In the CCS Folder add an
auth.txt file Text Doc. with your CCS password (case sensitive)