To activate the anti collision on the CCS.






To activate the anti collision on the CCS.






Operator says fan not blowing and AC unit was not switching on. Had to reset circuit breaker Q362F
Change the parameter in the slew drive to warning instead of fault.

Remove plug at 3 o’clock position. Oil level should be at threads or 1 CM below.

To fill, rotate hoist drum until one of the fill plugs is at 12 o’clock. Use APG 150 oil.
When trying hoist or lower line, drive immediately shuts off. Display on drive E65. The drive is not receiving a signal from speed sensors (there are 2 on the motor). Found 2 broken wires at crimped terminals on Speed Card (X3B).

To place KEB drive in a mode where it does not look for speed sensors, must be placed in Degraded Mode. Follow the steps in link below and also steps to put back into normal mode.
Can not apply more than 30% of speed or drive will shut down. (E66 code in degraded mode)
On MDT389, this did not work. Here are the other procedures, per JP.
75HPL Degrade Mode Instructions

When pressing the start button, green circle on LMI display toggles between circle and square, but does not try and start up drive. Only fault code was Motor Heating Circuit held open too long. Disable motor heating in configuration options screen.
Operator called and complained that the heater in the cab was not working. Wipers worked, and when switched over to AC the light would come on but no fan.
Had the operator power down the crane and unplug the KP plug and plug it back in. Heater started working again.
In case needed:
Q131A Heater Circuit Breaker
Q340A & Q342A Wiper Circuit Breakers
Q362A AC Circuit Breaker