IMT Knuckle Boom

The lights for the outriggers were not working.  Called IMT, we opened up the RCL 5300 which is the pad on the side with all the buttons, and found one of the wires 52, or 53, to be loose on the power side.  Took out and reconnected and all worked fine.

See pictures and electrical DiagramUntitled Extract Pages

 

 

Warning Light on RT Mobile Crane

Warning alarm and beeper going off in cab.

Recalibrate length indicator and angle sensor according to PAT manual (found in mobile crane folder).  Light would still go off at restart, but after any movements, light would go off.  Scoped all the way out and then back in, and light has remained off.

 

Bigge, biggie

Wacker Neuson Low Voltage

Generator was putting out 30-60 volts on singe phase setting and 110 on 3 phase setting.  Door switch was out of adjustment.   If the door switch is out of adjustment and not engaged the voltage will drop.

Crane only moves at slowest speed with all functions

Customer was operating MDT crane with remote, but all functions were slow.  Had the following icon on the display of the remote:

Crane was in P+ mode, which allows for greater capacity, but slows function.  On the remote this is controlled with ” A-B ” switch.

In the cab this is controlled by the gray button on the top of the left joystick.